Commit c085f11a authored by Seppia's avatar Seppia

Thermal Protection adjustments

Changes thermal histeresys to 10 degrees celsius and protection time to one minute.
parent 0e8fe2f6
......@@ -62,8 +62,8 @@
* If you get false positives for "Thermal Runaway" increase THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
/**
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
......