Commit a8d35315 authored by Seppia's avatar Seppia

Merge branch 'biond' into eigenDama

parents 6647f5bd edd51c1a
......@@ -86,7 +86,7 @@
// 10 is 100k RS thermistor 198-961 (4.7k pullup)
// 11 is 100k beta 3950 1% thermistor (4.7k pullup)
// 12 is 100k 0603 SMD Vishay NTCS0603E3104FXT (4.7k pullup) (calibrated for Makibox hot bed)
// 13 is 100k Hisens 3950 1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
// 13 is 100k Hisens 3950 1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
// 20 is the PT100 circuit found in the Ultimainboard V2.x
// 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
//
......@@ -228,15 +228,15 @@ The issue: If a thermistor come off, it will read a lower temperature than actua
The system will turn the heater on forever, burning up the filament and anything
else around.
After the temperature reaches the target for the first time, this feature will
start measuring for how long the current temperature stays below the target
After the temperature reaches the target for the first time, this feature will
start measuring for how long the current temperature stays below the target
minus _HYSTERESIS (set_temperature - THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).
If it stays longer than _PERIOD, it means the thermistor temperature
cannot catch up with the target, so something *may be* wrong. Then, to be on the
safe side, the system will he halt.
Bear in mind the count down will just start AFTER the first time the
Bear in mind the count down will just start AFTER the first time the
thermistor temperature is over the target, so you will have no problem if
your extruder heater takes 2 minutes to hit the target on heating.
......@@ -396,9 +396,9 @@ const bool Z_MAX_ENDSTOP_INVERTING = false; // set to true to invert the logic o
// these are the offsets to the probe relative to the extruder tip (Hotend - Probe)
// X and Y offsets must be integers
// TODO
#define X_PROBE_OFFSET_FROM_EXTRUDER -25
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35
#define X_PROBE_OFFSET_FROM_EXTRUDER -30
#define Y_PROBE_OFFSET_FROM_EXTRUDER 15
#define Z_PROBE_OFFSET_FROM_EXTRUDER -36.5
#define Z_RAISE_BEFORE_HOMING 10 // (in mm) Raise Z before homing (G28) for Probe Clearance.
// Be sure you have this distance over your Z_MAX_POS in case
......@@ -455,9 +455,9 @@ const bool Z_MAX_ENDSTOP_INVERTING = false; // set to true to invert the logic o
#endif
#endif
#endif
#endif // ENABLE_AUTO_BED_LEVELING
......@@ -473,15 +473,14 @@ const bool Z_MAX_ENDSTOP_INVERTING = false; // set to true to invert the logic o
//#define MANUAL_Z_HOME_POS 402 // For delta: Distance between nozzle and print surface after homing.
//// MOVEMENT SETTINGS
// TODO
#define NUM_AXIS 4 // The axis order in all axis related arrays is X, Y, Z, E
#define HOMING_FEEDRATE {50*60, 50*60, 4*60, 0} // set the homing speeds (mm/min)
#define HOMING_FEEDRATE {4000, 4000, 240, 0} // set the homing speeds (mm/min)
// default settings
// TODO estrusore soltanto
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,88.8888889,8000,200} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {500, 500, 300, 25} // (mm/sec)
#define DEFAULT_MAX_FEEDRATE {15000, 15000, 300, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E max acceleration in mm/s^2 for printing moves
......@@ -663,7 +662,7 @@ const bool Z_MAX_ENDSTOP_INVERTING = false; // set to true to invert the logic o
// Shift register panels
// ---------------------
// 2 wire Non-latching LCD SR from:
// https://bitbucket.org/fmalpartida/new-liquidcrystal/wiki/schematics#!shiftregister-connection
// https://bitbucket.org/fmalpartida/new-liquidcrystal/wiki/schematics#!shiftregister-connection
//#define SAV_3DLCD
#ifdef SAV_3DLCD
......@@ -762,9 +761,9 @@ const bool Z_MAX_ENDSTOP_INVERTING = false; // set to true to invert the logic o
* Support for a filament diameter sensor
* Also allows adjustment of diameter at print time (vs at slicing)
* Single extruder only at this point (extruder 0)
*
*
* Motherboards
* 34 - RAMPS1.4 - uses Analog input 5 on the AUX2 connector
* 34 - RAMPS1.4 - uses Analog input 5 on the AUX2 connector
* 81 - Printrboard - Uses Analog input 2 on the Exp1 connector (version B,C,D,E)
* 301 - Rambo - uses Analog input 3
* Note may require analog pins to be defined for different motherboards
......@@ -781,7 +780,7 @@ const bool Z_MAX_ENDSTOP_INVERTING = false; // set to true to invert the logic o
#define MAX_MEASUREMENT_DELAY 20 //delay buffer size in bytes (1 byte = 1cm)- limits maximum measurement delay allowable (must be larger than MEASUREMENT_DELAY_CM and lower number saves RAM)
//defines used in the code
#define DEFAULT_MEASURED_FILAMENT_DIA DEFAULT_NOMINAL_FILAMENT_DIA //set measured to nominal initially
#define DEFAULT_MEASURED_FILAMENT_DIA DEFAULT_NOMINAL_FILAMENT_DIA //set measured to nominal initially
//When using an LCD, uncomment the line below to display the Filament sensor data on the last line instead of status. Status will appear for 5 sec.